VSDP4-Series (Variable Speed Drive Panel)

Benefits

  • Energy Savings
  • Improved Process Reliability
  • Soft Starting & Stopping
  • Process Efficiency
  • Improved Process Control
  • Lower Maintenance Cost

The VSDN4 series is a variable speed drive panel package. The VSD-4 series panel an industry first VFD in a UL Listed Type 4 enclosure with Heat Guard powder coat finish.

Features

  • UL Listed Single Phase Coversion and as Service Entrance Equipment
  • Wide Range of Voltage Inputs 480(342-528) and 230(180-264)
  • 1000 FT Motor Cable Length (No Load Reactors)
  • Constant Pressure with Variable Flow
  • Well Draw Down Control
  • Operate Pump at BEP
  • Empty Pipe Fill Mode
  • Dry Pump Detection
  • Automatic Energy Optimization
  • End of Pump Curve Detection
  • Auto Tuning
  • Type 3R Steel Enclosure
  • View All Features
  • Heat Guard Solar White Powder Coating Finish
  • Fan and Filter Provided as Standard Feature for Heat Dissipation
  • Full Foam-In-Place Gasket Hinged Door with Provisiion for a Padlock
  • Keypad Sun Shield with Provision for Padlock
  • 122 °F(50 °C) Outside Temperature, Non-Direct Sunlight
  • Heavy Duty Flange Fusible or Circuit Breaker Disconnect Switch
  • Thermal Protection
  • Conformal Coated PCBs
  • Input DC-Link Reactors
  • Motor Winding Pre-Heat
  • Motor Thermistor Monitoring
  • Single Phase Line Supply
  • Graphical Display
  • Remote Communications

Options

  • Option
  • Option
  • Option
  • Option
  • Option

Applications

  • Water Projects
  • Oil & Gas Industry
  • Mining & Metal Applications

Download the Schematic for this product.

Features

  • UL 508a
  • Altivar Process Drive
  • Access to Real-Time Data
  • Power User Interfaces
  • Flexible Communications
  • Built-in Pump Protection Functions
  • Multiple Configurations and Options
  • Easy-to-Maintain Design
  • UL Type 3R Enclosure
  • Fan Cooled (Vent to the sides of the enclosure)
  • Easily Serviced Cooling Fan
  • Form-in-Place Gasket
  • Heat Guard Solar White Powder Coat Finish
  • Flange Mount Disconnect
  • Door Mounted HMI w/ Keypad Cover

Options

  • Power On Pilot Light
  • Run Pilot Light
  • Fault Pilot Light
  • HOA Switch
  • Lighting Arrestor
  • Speed Pot Control
  • Input Line Reactor
  • Remote Run Signal Interposing Relay
  • Surge Suppressor
  • Motor Terminal Block
  • DVDT
  • Enclosure Heater
  • Rest Push Button
  • Contractor Bypass
  • Harmonic Filter
  • Load Reactor
  • Ethernet IP Option Card

Fusible Disconnect, Main Disconnect 460V 3P

**Swipe left/right to view full table

MCI Part Number NB Maximum HP SUB Maximum HP Fused Disconnect Size VFD Maximum Amps Enclosure Size Weight
VSDP4005N4FD 5 3 30 8 36" x 30" x 10" 95 n/a
VSDP4007N4FD 7.5 5 30 11 36" x 30" x 10" 100 n/a
VSDP4010N4FD 10 7.5 30 15 36" x 30" x 10" 100 n/a
VSDP4015N4FD 15 10 30 21 36" x 30" x 10" 115 n/a
VSDP4020N4FD 20 15 60 27 36" x 30" x 10" 135 n/a
VSDP4025N4FD 25 20 60 34 36" x 30" x 120 150 n/a
VSDP4030N4FD 30 25 60 40 48" x 30" x 10" 150 n/a
VSDP4040N4FD 40 30 100 52 46" x 24" x 16" 150 n/a
VSDP4050N4FD 50 40 100 65 48" x 30" x 10" 175 n/a
VSDP4060N4FD 60 50 100 80 48" x 30" x 10" 175 n/a
VSDP4075N4FD 75 60 200 105 48" x 30" x 10" 175 n/a
VSDP4100N4FD 100 75 200 130 54" x 36" x 12" 250 n/a
VSDP4125N4FD 125 100 200 160 54" x 36" x 12" 250 n/a

NOTES:
*Size the VSDP based on the maximum current requirements and not based on HP rating
*Refer to notes on sizing VSDP and table VSDP-1 for possible maximum amp requirements per different motor type and pumping applications
*Fuses are included

Circuit Breaker - Main Disconnect 460V 3P

**Swipe left/right to view full table

MCI Part Number NB Maximum HP SUB Maximum HP Circuit Breaker Size VCB Maximum Amps Enclosure Size Weight
VSDP4005N4CB 5 3 30 8 36" x 30" x 10" 95 n/a
VSDP4007N4CB 7.5 5 30 11 36" x 30" x 10" 100 n/a
VSDP4010N4CB 10 7.5 30 15 36" x 30" x 10" 100 n/a
VSDP4015N4CB 15 10 30 21 36" x 30" x 10" 115 n/a
VSDP4020N4CB 20 15 60 27 36" x 30" x 10" 135 n/a
VSDP4025N4CB 25 20 60 34 36" x 30" x 120 150 n/a
VSDP4030N4CB 30 25 60 40 48" x 30" x 10" 150 n/a
VSDP4040N4CB 40 30 100 52 46" x 24" x 16" 150 n/a
VSDP4050N4CB 50 40 100 65 48" x 30" x 10" 175 n/a
VSDP4060N4CB 60 50 100 80 48" x 30" x 10" 175 n/a
VSDP4075N4CB 75 60 200 105 48" x 30" x 10" 175 n/a
VSDP4100N4CB 100 75 200 130 54" x 36" x 12" 250 n/a
VSDP4125N4CB 125 100 200 160 54" x 36" x 12" 250 n/a

NOTES:
*Size the VSDP based on the maximum current requirements and not based on HP rating
*Refer to notes on sizing VSDP and table VSDP-1 for possible maximum amp requirements per different motor type and pumping applications
*Fuses are included

Fusible Disconnect, Main Disconnect 230V 3P

**Swipe left/right to view full table

MCI Part Number NB Maximum HP SUB Maximum HP Fusible Size VFD Maximum Amps Enclosure Size Weight
VSDP2003N4FD 3 2 30 10.6 36" x 30" x 10" 133 n/a
VSDP2005N4FD 5 3 30 16.7 36" x 30" x 10" 133 n/a
VSDP2007N4FD 7.5 5 30 24.2 36" x 30" x 10" 139 n/a
VSDP2010N4FD 10 7.5 60 30.8 36" x 30" x 10" 139 n/a
VSDP2015N4FD 15 10 60 46.2 36" x 30" x 10" 139 n/a
VSDP2020N4FD 20 15 100 59.4 48" x 30" x 10" 150 n/a
VSDP2025N4FD 25 20 100 74.8 48" x 30" x 10 175 n/a
VSDP2030N4FD 30 25 100 88.0 48" x 30" x 10" 175 n/a
VSDP2040N4FD 40 30 200 115.0 48" x 30" x 10" 175 n/a
VSDP2050N4FD 50 40 200 143.0 54" x 36" x 12" 250 n/a
VSDP2060N4FD 60 50 200 170.0 54" x 36" x 12" 175 n/a

NOTES:
*Size the VSDP based on the maximum current requirements and not based on HP rating
*Refer to notes on sizing VSDP and table VSDP-1 for possible maximum amp requirements per different motor type and pumping applications
*Fuses are included

Circuit Breaker, Main Disconnect 230V 3P

**Swipe left/right to view full table

MCI Part Number NB Maximum HP SUB Maximum HP Circuit Breaker Size VCB Maximum Amps Enclosure Size Weight
VSDP2003N4CB 3 2 30 10.6 36" x 30" x 10" 133 n/a
VSDP2005N4CB 5 3 30 16.7 36" x 30" x 10" 133 n/a
VSDP2007N4CB 7.5 5 30 24.2 36" x 30" x 10" 139 n/a
VSDP2010N4CB 10 7.5 60 30.8 36" x 30" x 10" 139 n/a
VSDP2015N4CB 15 10 60 46.2 36" x 30" x 10" 139 n/a
VSDP2020N4CB 20 15 100 59.4 48" x 30" x 10" 150 n/a
VSDP2025N4CB 25 20 100 74.8 48" x 30" x 10 175 n/a
VSDP2030N4CB 30 25 100 88.0 48" x 30" x 10" 175 n/a
VSDP2040N4CB 40 30 200 115.0 48" x 30" x 10" 175 n/a
VSDP2050N4CB 50 40 200 143.0 54" x 36" x 12" 250 n/a
VSDP2060N4CB 60 50 200 170.0 54" x 36" x 12" 175 n/a

NOTES:
*Size the VSDP based on the maximum current requirements and not based on HP rating
*Refer to notes on sizing VSDP and table VSDP-1 for possible maximum amp requirements per different motor type and pumping applications